rewindex

RewindexCVEsMongoDB Atlas

CVE-2026-19003: MongoDB BI Connector ODBC driver may write outside an allocated buffer when the setup dialog opens a data source with oversized path settings

High · CVSS 7.8 (CVSS 3.1)EPSS 0.21%, 11th percentilePublished Updated Assigner: mongodb

Description

A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.

Vector CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H · CWE-121

Tracked companies

MongoDB Atlas

Mapped from the CVE’s affected-product data, NVD CPE matches, vendor advisories or package feeds. A mapping means the vendor’s software is named, not that its hosted service was exposed.

Status incidents that name it

No tracked status incident names this CVE.

Affected vendors and products

MongoDB: BI Connector ODBC Driver

References

All CVEsMarkdownJSON