Rewindex

ChangesTwingateIssue with Twingate

Twingate: Major incident: Issue with Twingate

Major incidentmajor (vendor)Changed Detected stspg.io (opens in new tab)
Summary

Summary pending. The diff below shows exactly what changed.

Incident page: the full timeline of updates

What changed

Struck in red is what Twingate removed; blue is what they added. Muted text is unchanged context.

AddedTitle#1
Before: not present
After: Issue with Twingate
AddedImpact#2
Before: not present
After: major
AddedStatus#3
Before: not present
After: postmortem
AddedStart time#4
Before: not present
After: 2022-05-13 15:38 UTC
AddedResolved time#5
Before: not present
After: 2022-05-13 17:17 UTC
AddedAffected components#6
Before: not present
After: Admin API, Admin Console, Admin Console - Admin Web Interface, Authentication - Enterprise, Authorization, Connector Heartbeat, Controller - Connection Authorization, Controller - Controller, Controller - IdP Synchronization, Controller - User Authentication, MFA, Public API
AddedUpdateinvestigating#7
Before: not present
After: We are currently investigating the incident.
AddedUpdateinvestigating#8
Before: not present
After: We have seen improvements; we are monitoring the situation. We'll update as we find out more details on the issue.
AddedUpdateinvestigating#9
Before: not present
After: We are continuing to investigate this issue.
AddedUpdateinvestigating#10
Before: not present
After: The system is fully up. We will continue to monitor.
AddedUpdateresolved#11
Before: not present
After: We are marking this issue resolved. The impact was between 8:31 am to 8:44 am. We will add the post mortem to the incident as soon as we have it ready.
AddedUpdatepostmortem#12
Before: not present
After: **Summary** At approximately 15:31 UTC on May 13, 2022, we received alerts from our monitoring systems pointing to a problem with Twingate. Our cloud provider’s load balancer started to return 502 \(Bad Gateway Error\) due to issues with our backend system. Looking into our backend logs, we noticed only 10-15% of requests were being handled properly and decided to restart our application pod in our Kubernetes cluster. Once the backend application pod restarted, the load balancer stopped returning 502 errors and things returned to normal around 15:44 UTC. During the outage, both our private and public APIs were affected. These APIs are used to drive most of the functionality that end users and administrators experience in Twingate. Specifically, this means that customers’ admin consoles were not accessible, the public API was not responsive to requests, and Clients and Connectors were unable to initiate authentication. Existing connections continued to function as a part of our reliability efforts completed in Q1 of 2022 \(provided that the clients and connectors were running the latest versions\). With this, we recommend that all of our customers upgrade their Clients and Connectors as soon as they can. **Root cause** After a detailed investigation, we found potential network glitches that caused connectivity issues and higher latency with different and unrelated parts of our system. While some components self-healed \(i.e. our Redis instance\), our main backend application was impacted. This was due to a much higher latency associated with a 3rd party service we use, leading to connection saturation of our API layer and the resulting rejection of additional requests, which manifested as 502 errors to the requestor. **Corrective actions** In order to mitigate the risk of this root cause impacting our service in the future, we have initiated a number of improvements: * Completed: We increased CPU and memory reservation for our backend application and relay pods. We decreased the connection timeout threshold for the third party so it doesn’t cause connection saturation again. * Short-term: We are working on adding more metrics and enabling more logging to help with investigation and post-mortem analysis in the future. * Medium Term: While we already had some circuit breaker capabilities and flags to turn off certain features, we will look for a complete service mesh solution with circuit breaker capabilities that should keep upstream applications and APIs running when issues and latencies arise for downstream dependencies.

First version of this incident archived by Rewindex. View the live incident (opens in new tab).

History of this incident

Friday, May 13, 2022

1 incident change