rewindex

RewindexCVEs

CVE-2024-8957: PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration

High · CVSS 7.2 (CVSS 3.1)KEV known exploitedEPSS 79.8%, 100th percentilePublished Updated Assigner: VulnCheck

In CISA’s Known Exploited Vulnerabilities catalog: PTZOptics PT30X-SDI/NDI Cameras OS Command Injection Vulnerability.

Added , federal remediation due . Known ransomware use: Unknown.

Required action: Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

Description

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

Vector CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H · CWE-78

Status incidents that name it

No tracked status incident names this CVE.

Affected vendors and products

ptzoptics: pt30x-ndi_firmwareptzoptics: pt30x-sdi_firmwarePTZOptics: PT30X-NDIPTZOptics: PT30X-SDI

References

All CVEsMarkdownJSON